Single use, 100% ETO gas cartridges available in
the following size: 20, 40, 50, 100 & 170 gms
ETO Sterilizer Standard Chamber Dimensions (For Hospital Use)
1.
1 Cu. Ft.
12” (H) x 12” (W) x 12” (D)
300 x 300 x 300 mm
2.
2 Cu. Ft.
12” (H) x 12” (W) x 24” (D)
300 x 300 x 600 mm
3.
4 Cu. Ff.
12” (H) x 12” (W) x 48” (D)
300 x 300 x 1200 mm
4.
5 Cu. Ff.
15” (H) x 18” (W) x 36” (D)
375 x 450 x 900 mm
5.
8 Cu. Ff.
18” (H) x 18” (W) x 42” (D)
450 x 450 x 1050 mm
Made for Hospitals : 100% ETO gas cartridges use exact dosage “as per chamber size”. No bulky cylinders to be used by inexperienced personnel, causing leakages and hence health and FIRE & SAFETY hazards.
Safe and Easy Handling: ETO gas cartridges is punctured in the chamber only when proper negative pressure and humidity conditions are achieved in the chamber.
Ease of Operation: Cold Cycle (40°C), Warm Cycle (55°C), 7 more user-defined cycles available.
Ease of Handling: Material can be easily loaded using the Basket provided.
Built in Aeration cycle: Aeration is carried out at the end of the cycle inside the chamber itself.
Wide spectrum of usage:
All kinds of medical devices and instruments can be sterilized.
Ideal for sterilization of heat / moisture sensitive medical equipment and instruments
ETO is the most effective, safe, fully validated and economical method of sterilization.
Effective against all Micro-organisms, including resistant spores.
Installation: Machine can be installed in-wall or placed on a free-standing rack.
Sterile Chain Intergrity: Double door models are available for clean room application to maintain sterile chain integrity.
Low cost per cycle: Lowest operating costs compared to other available options.
Advantages of ETO Sterilizer Superior Automation:
Best in class Automation and latest SCADA software make remote control and monitoring of all cycle parameters possible.
During Sterilization a Microprocessor / PLC controls temperature, Moisture, Gas Injection, Gas Exposure and all critical time and pressure based parameters.
Important sterilization parameters like Phase Status, Current Values & set values, continuously displayed at all times on Controller Screen & on Remote Computer via SCADA software.
Continuous display of Temperature, Humidity and Pressure On-line allows user to be aware of Cycle status at all times.
Temperature uniformly and accurately maintained throughout the chamber to within ± 3°C of the Set Sterilization temperature.
Error Code and alarm is generated and cycle stops automatically in case any error occurs. Computer Screen displays Error and possible cause and remedy.
The advanced SCADA software provided stores detailed records of Process-Data for every cycle.
Reports are available in Data, Summary and Graph formats for every batch of goods sterilized.
User can re-print reports as and when required, using any normal printer.
Digital storage of data cuts cost, saves space, ensures safety of data and negates cost of expensive thermal printing.